smartline st800 pressure transmitters
SmartLine STA800 - Absolute Pressure
SmartLine® ST800 Absolute Pressure Transmitters are used in vacuum applications that require high accuracy. The transmitters are ideal for low-pressure measurement in vacuum distillation columns.
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
| STA822/STA82L | 0 to 780 mmHga | 0 to 1,040 mbara |
| STA840/STA84L | 0 to 500 psia | 0 to 35 bara |
| STA87L | 0 to 3000 psia | 0-207 bara |
Others
- Accuracy
- 0.025% (optional)
- Up to 0.0375% of span (standard)
- Wiring
- Up to 16 AWG (1.5 mm diameter)
- Wetted Materials
- 316L Stainless Steel
- Gold-plated options
- Hastelloy C-276
- Monel 400
- Tantalum
- Supply Voltage
- DE: 15 to 49.3 VDC
- FF: 9 to 32 VDC
- HART: 10.8 to 42.4 VDC
- Stability
- Up to 0.01% of URL per year for 15 years
- Sensor Technology
- Piezoresistive sensor with on-chip temperature compensation
- Safety Approvals
- Dual Seal design
- NAMUR NE-107 Extended Diagnostics
- SIL 2/3 certified
- Relative Humidity
- 0 to 100% RH
- Rangeability
- Up to 100:1
- Range
- STA822: 780 mmHgA (1040 mbarA)
- STA82L: 780 mmHgA
- STA840: 500 psia (35 barA)
- STA84L: 500 psia
- STA87L: 3000 psia (210 barA)
- Process Connections Type
- 1/2 in NPT (Female), DIN 19213, others
- Models
- STA822
- STA82L
- STA840
- STA84L
- STA87L
- Minimum Span
- STA822/82L: 50 mmHgA (66.7 mbarA)
- STA840/84L: 5 psia (0.35 barA)
- STA87L: 30 psia (2.1 barA)
- Measurement Type
- Absolute Pressure
- Maximum Turndown Ratio
- STA822/82L: 15:1
- STA840/84L/87L: 100:1
- Marine Certification
- ABS
- BV
- DNV
- KR
- LR
- Fill Fluids
- CTFE
- Silicone 200
- Silicone 704
- Display
- Configurable Units
- Modular LCD (Alphanumeric or Advanced Graphics)
- Multiple Screens
- Diagnostics
- Comprehensive On-board Diagnostics
- Plugged Impulse Line Detection (PILD) option
- CustomerMarketing-Industry
- Chemicals
- Life Sciences
- Manufacturing
- Mining, Minerals & Metals
- Utilities
- Configuration
- External Zero, Span, & Configuration Capability
- Three-Button Local Configuration
- Communications
- 4 to 20 mA
- FOUNDATION Fieldbus
- HART (v7.0)
- Honeywell DE
- Approvals
- ATEX
- CCoE
- CSA
- EAC
- FM
- IEC 61508 SIL 2/3
- IECEx
- INMETRO
- KOSHA
- Marine (ABS, BV, DNV, KR, LR)
- NEPSI
- SAEx
- UATR
- Ambient Temperature Limits
- -40 to +85 deg C (Ambient)
- -55 to +125 deg C (Meter Body, Model Dependent)
Others
- Accuracy
- 0.025% (optional)
- Up to 0.0375% of span (standard)
- Wiring
- Up to 16 AWG (1.5 mm diameter)
- Wetted Materials
- 316L Stainless Steel
- Gold-plated options
- Hastelloy C-276
- Monel 400
- Tantalum
- Supply Voltage
- DE: 15 to 49.3 VDC
- FF: 9 to 32 VDC
- HART: 10.8 to 42.4 VDC
- Stability
- Up to 0.01% of URL per year for 15 years
- Sensor Technology
- Piezoresistive sensor with on-chip temperature compensation
- Safety Approvals
- Dual Seal design
- NAMUR NE-107 Extended Diagnostics
- SIL 2/3 certified
- Relative Humidity
- 0 to 100% RH
- Rangeability
- Up to 100:1
- Range
- STA822: 780 mmHgA (1040 mbarA)
- STA82L: 780 mmHgA
- STA840: 500 psia (35 barA)
- STA84L: 500 psia
- STA87L: 3000 psia (210 barA)
- Process Connections Type
- 1/2 in NPT (Female), DIN 19213, others
- Models
- STA822
- STA82L
- STA840
- STA84L
- STA87L
- Minimum Span
- STA822/82L: 50 mmHgA (66.7 mbarA)
- STA840/84L: 5 psia (0.35 barA)
- STA87L: 30 psia (2.1 barA)
- Measurement Type
- Absolute Pressure
- Maximum Turndown Ratio
- STA822/82L: 15:1
- STA840/84L/87L: 100:1
- Marine Certification
- ABS
- BV
- DNV
- KR
- LR
- Fill Fluids
- CTFE
- Silicone 200
- Silicone 704
- Display
- Configurable Units
- Modular LCD (Alphanumeric or Advanced Graphics)
- Multiple Screens
- Diagnostics
- Comprehensive On-board Diagnostics
- Plugged Impulse Line Detection (PILD) option
- CustomerMarketing-Industry
- Chemicals
- Life Sciences
- Manufacturing
- Mining, Minerals & Metals
- Utilities
- Configuration
- External Zero, Span, & Configuration Capability
- Three-Button Local Configuration
- Communications
- 4 to 20 mA
- FOUNDATION Fieldbus
- HART (v7.0)
- Honeywell DE
- Approvals
- ATEX
- CCoE
- CSA
- EAC
- FM
- IEC 61508 SIL 2/3
- IECEx
- INMETRO
- KOSHA
- Marine (ABS, BV, DNV, KR, LR)
- NEPSI
- SAEx
- UATR
- Ambient Temperature Limits
- -40 to +85 deg C (Ambient)
- -55 to +125 deg C (Meter Body, Model Dependent)
- Accuracy : 0.025% (optional)|Up to 0.0375% of span (standard)
- Wiring : Up to 16 AWG (1.5 mm diameter)
- Wetted Materials : 316L Stainless Steel|Gold-plated options|Hastelloy C-276|Monel 400|Tantalum
- Supply Voltage : DE: 15 to 49.3 VDC|FF: 9 to 32 VDC|HART: 10.8 to 42.4 VDC
- Stability : Up to 0.01% of URL per year for 15 years
- Sensor Technology : Piezoresistive sensor with on-chip temperature compensation
- Safety Approvals : Dual Seal design|NAMUR NE-107 Extended Diagnostics|SIL 2/3 certified
- Relative Humidity : 0 to 100% RH
- Rangeability : Up to 100:1
- Range : STA822: 780 mmHgA (1040 mbarA)|STA82L: 780 mmHgA|STA840: 500 psia (35 barA)|STA84L: 500 psia|STA87L: 3000 psia (210 barA)
- Process Connections Type : 1/2 in NPT (Female), DIN 19213, others
- Models : STA822|STA82L|STA840|STA84L|STA87L
- Minimum Span : STA822/82L: 50 mmHgA (66.7 mbarA)|STA840/84L: 5 psia (0.35 barA)|STA87L: 30 psia (2.1 barA)
- Measurement Type : Absolute Pressure
- Maximum Turndown Ratio : STA822/82L: 15:1|STA840/84L/87L: 100:1
- Marine Certification : ABS|BV|DNV|KR|LR
- Fill Fluids : CTFE|Silicone 200|Silicone 704
- Display : Configurable Units|Modular LCD (Alphanumeric or Advanced Graphics)|Multiple Screens
- Diagnostics : Comprehensive On-board Diagnostics|Plugged Impulse Line Detection (PILD) option
- CustomerMarketing-Industry : Chemicals|Life Sciences|Manufacturing|Mining, Minerals & Metals|Utilities
- Configuration : External Zero, Span, & Configuration Capability|Three-Button Local Configuration
- Communications : 4 to 20 mA|FOUNDATION Fieldbus|HART (v7.0)|Honeywell DE
- Approvals : ATEX|CCoE|CSA|EAC|FM|IEC 61508 SIL 2/3|IECEx|INMETRO|KOSHA|Marine (ABS, BV, DNV, KR, LR)|NEPSI|SAEx|UATR
- Ambient Temperature Limits : -40 to +85 deg C (Ambient)|-55 to +125 deg C (Meter Body, Model Dependent)
Brochure
Data Sheet
White Paper
Filters
Please Sign In to view part numbers available for purchase based on your account
Please sign in to view part numbers available for purchase based on your account Sign In